ISO 18319-2:2022 pdf download.Fibre reinforced polymer (FRP) reinforcement for concrete structures — Part 2: Specifications of CFRP strips.
This document specifies requirements for unidirectional carbon fibre-reinforced polymer (CFRP) strips as external-bonded reinforcements on the concrete substrate. This document is applicable for the CFRP strips that:
— consist of carbon fibre and thermoset resin;
— are manufactured by pultrusion method;
— have a carbon fibre fraction over 60 % by volume; and
— have a thickness within 3 mm.
This document specifies the methodologies to express the mechanical properties as characteristic values, appearance and dimensions, and sampling test.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 10406-3, Fibre-reinforced polymer (FRP) reinforcement of concrete — Test methods — Part 3: CFRP strips
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1 straightness
lateral warped deformation perpendicular to the longitudinal axis of strip
3.2 initial inspection
inspection carried out by the manufacturer of the product for the initial production from the relevant production apparatus, and the cases of change in the production method, product design and raw materials to be used
4.3 Straightness
Tolerance of straightness in sampling test specified in Clause 6 shall not be larger than 0,5 mm.
5 Mechanical properties
5.1 General
The mechanical properties of CFRP strips shall be expressed by the characteristic values of tensile strength, Young’s modulus, and ultimate strain.
NOTE This requirement is to be met by the manufacturer of the product. The properties for design are calculated from the characteristic values, as prescribed in an appropriate design code which is in accordance with ISO 14484.
5.2 Characteristic value of tensile strength and Young’s modulus
The characteristic value of tensile strength and characteristic value of Young’s modulus of CFRP strips shall be agreed between interested parties.
5.3 Characteristic value of ultimate strain
The characteristic value of ultimate strain shall be determined by the characteristic value of tensile strength divided by the characteristic value of Young’s modulus.
6 Sampling test
6.1 Dimensions
6.1.1 Width, thickness and cross-sectional area
The width of CFRP strips shall be measured with an interval of 10 m in length by a calliper, expressed with a precision of 0,1 mm rounded down to the first decimal place.
The thickness of CFRP strips shall be measured with an interval of 10 m in length by a calliper, expressed with a precision of 0,1 mm rounded down to the first decimal place.
The cross-sectional area of CFRP strips shall be determined by multiplying the width and the thickness,expressed with a precision of 0,1 mm 2 rounded down to the first decimal place.
6.1.2 Length
In case the nominal length is equal to or larger than 5 m, the length of CFRP strips shall be measured by a roller type length measuring device with rolling up the strip, expressed with a precision of 0,1 m rounded down to the first decimal place.
In case the nominal length is smaller than 5 m, the length of CFRP strips shall be measured by a metallic tape measure for the flattened strip, expressed with a precision of 0,01 m rounded down to the second decimal place.
6.1.3 Straightness
Straightness of CFRP strips shall be measured in accordance with following procedure.
a) Place the flattened strip on a surface plate.
b) A metallic scale with 1 m length (long scale) shall be disposed along the axis of the strip. Other metallic scale shall be placed perpendicularly at the central position of the long scale as shown in Figure 1.
c) The interstice between the strip and the long scale shall be measured with a precision of 0,1 mm rounded down to the first decimal place.ISO 18319-2 pdf download.ISO 18319-2 pdf download